How do I control metal contamination in powder, and where do the magnet and detector go?
Metal contamination comes from three places: wear on equipment (mill liners, torn screens, screw flight edges), the raw material itself, and packaging (staples, clips, bag seals). Control points follow the process order rather than being bolted on wherever there is space.
The first sits after milling and before screening: a neodymium magnet array rated 9000 gauss or more at the surface, cleaned every shift with the iron catch weighed and logged. A sudden rise in catch weight is an early signal of a worn mill or a damaged screen. The second sits after screening, as a metal detector, with the usual sensitivities quoted at 1.5 mm ferrous, 2.0 mm non-ferrous and 2.5 mm stainless steel. The third sits before packing, as a final check on the finished lot, or as X-ray inspection, which also catches glass and stone.
Two traps are real. Stainless 316 is weakly magnetic and will pass a detector running in ferrous mode almost untouched, so stainless sensitivity has to be validated separately and the test piece has to travel through the actual product path. And a flowing powder generates phase noise, so the detector needs a bulk-product setting with the phase correctly trimmed — widening the sensitivity to quiet the noise is the same as not having a detector.
Keep the records: verify with certified test pieces once per shift and file the result alongside the magnet cleaning log. Being able to show the equipment was working at the time is worth far more than an explanation afterwards.