001How is D50 measured, and can results from different labs be compared?D50 is the median of the cumulative particle size distribution, usually measured by laser diffraction. Different instruments and different dispersion conditions can produce quite different numbers. Th…
002How do you control batch-to-batch variation?Three things: a stable raw material source, fixed process parameters, and per-batch testing before shipment. Powder production is most exposed to changes in deposit or supplier; once the impurity prof…
003Why do powders agglomerate and how can it be prevented?There are two types, soft and hard agglomerates, and they require completely different responses. Soft agglomerates are held by van der Waals forces and static and can be broken by dispersion. Hard ag…
004What cleanliness class is the production environment?Cleanliness control for powder production differs from liquids: powders do not readily support microbial growth, so dust control and cross-contamination prevention are the focus. Key control points in…
005Do you keep retention samples and for how long?Yes. Retention samples are kept for a defined period after each batch ships, with the duration depending on product type and customer agreement. Custom grades are retained longer because they correspo…
006How are quality issues handled?Step one is always to freeze the information: keep the physical sample from the affected batch, record the use conditions, and establish how the anomaly can be reproduced. Without those three, any con…
007My loose powder flies everywhere and does not adhere well. How do I fix it from the powder side?Flying powder is mostly excess fines plus static, while poor adhesion is insufficient affinity between powder and skin. They often appear together but have different causes. Start with the particle si…
008Do cosmetic powders need sterilisation, and what does each method cost?Start with the conclusion: not every powder needs sterilisation. Powders are low in moisture and low in water activity, and the microbial load usually comes from packaging, the environment and storage…
009How do I control metal contamination in powder, and where do the magnet and detector go?Metal contamination comes from three places: wear on equipment (mill liners, torn screens, screw flight edges), the raw material itself, and packaging (staples, clips, bag seals). Control points follo…