What is the relationship between specific surface area and oil absorption?

Broadly positively correlated, but not linear, and porous grades deviate most.

BET specific surface area measures the total accessible area including pore walls; oil absorption measures how much oil those surfaces can hold. Larger area and accessible pore volume generally mean higher oil absorption. Fumed silica at around 200 m²/g can exceed 300 ml/100 g, while ground calcium carbonate below 5 m²/g sits at 15-20.

The correlation breaks down in two cases. First, closed porosity: some porous powders show a large surface area but the pore openings are too narrow for larger oil molecules to enter, so real oil absorption stays low. Second, surface treatment: silane or silicone coating occupies part of the surface, dropping BET by 10-30% while reducing absorption and absorption rate even more.

So never select on one number. Oil absorption answers oil control, surface area answers dispersion and reinforcement, and surface treatment answers skin feel — three different questions.